Abstract

Potentially induced degradation (PID) faults in crystalline silicon photovoltaic modules are a well-known problem. Traditional detection methods are time-consuming and expensive. In order to quickly detect the PID PV modules online, we investigate and collect the PID PV modules in several large PV power plants. The I-V characteristics of the PID modules are tested. The test results show that the open circuit voltage of PID modules has a significantly decline than that of the normal modules. In addition, the open circuit voltage has a large difference under high and low irradiance, and the reason of this feature is analyzed. A method for online diagnosis of PV module PID faults through I-V curve is proposed, and it has been verified that the method is effective for PID faults.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.