Abstract

This study was aimed at developing a new method for detecting the sodium-water reaction as a result of a water leakage into the liquid sodium boundary for the liquid metal reactor. In the case of a passive acoustic method, to develop the leak detection algorithm, several signal processing methods have been evaluated. When the acoustic emission signal has a relatively high signal-to-noise ratio for the acoustic noises the spectral estimation method could be used to detect the sodium water reaction. In the case of a low signal-to-noise ratio within -5 dB to -15 dB, the system modeling and the identification methods using an autoregressive and an adaptive algorithm could be used to detect the sodium-water reaction. Regarding the active acoustic method, the basic attenuation factors of the ultrasonic beam were evaluated in the case of normal and abnormal plant conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.