Abstract

In order to ensure the stable operation, improve efficiency, and enhance sustainability of wastewater treatment systems, this paper investigates the fault detection problem in wastewater treatment process based on an improved kernel extreme learning machine method. Firstly, a kernel extreme learning machine (KELM) model optimized by an improved mutation bald eagle search (IMBES) optimizer is proposed to generate point predictions of effluent quality parameters. Then, based on the point prediction results, the confidence interval of effluent quality parameters is calculated using kernel density estimation (KDE) method. This interval represents the bounds of system uncertainty and unknown disturbance at normal conditions and can be treated as the threshold for fault diagnosis. Finally, the effectiveness of the proposed method is illustrated by two datasets obtained from the BSM1 wastewater simulation platform and an actual water platform. Experimental results show that compared with other methods such as CNN, LSTM, and IBES-LSSVM, this method has a significant improvement in prediction accuracy, and at the same confidence level, it ensures fault detection rate while generating smaller confidence intervals.