Abstract
Sensors deployed in the Columbia River estuary gather information on physical dynamics and changes in estuary habitat. Of these sensors, conductivity sensors are particularly susceptible to biofouling, which gradually degrades sensor response and corrupts critical data. Several weeks may pass before degradation is visibly detected. Since the onset time of biofouling is unknown, an indeterminate amount of measurement data is corrupted. To speed detection and minimize data loss, we develop automatic biofouling detectors based on machine learning approaches for these conductivity sensors. We demonstrate that our detectors identify biofouling at least as reliably as human experts. In addition, these detectors provide accurate estimates of biofouling onset time. Real‐time detectors installed during the summer of 2001 produced no false alarms yet detected all episodes of sensor degradation before the field staff.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.