It is recognized that the control surface fault is detected by monitoring the value of the coefficients due to the control surface deviation. It is found out the control surface stuck position by comparing the trim value with the reference value. To detect and isolate the fault, two mixed methods apply to the real-time parameter estimation and similarity measure. If the scatter of aerodynamic coefficients for the fault and normal are closing nearly, fault decision is difficult. Applying similarity measure to decide for fault or not, it makes a clear and easy distinction between fault and normal. Low power processor is applied to the real-time parameter estimator and computation of similarity measure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.