Abstract

Fault detection and diagnosis is important in ensuring the stability and safety of chemical processes. However, limited studies have focused on strong periodic disturbance and non-Gaussian process monitoring. By utilizing the data-driven monitoring method, we have proposed the residual analysis independent component analysis based on average multivariate cumulative sum (AMRA-ICA) method to avoid the influence of periodic disturbance in non-Gaussian chemical processes with periodic disturbance. Average multivariate cumulative sum (AM) is introduced in the AMRA-ICA method for disturbance cycle synchronization. Residual analysis (RA) is employed to remove the disturbance in the data set and to obtain the normal residual. The independent component analysis (ICA) method is then utilized to monitor the residual, and an improved contribution histogram method is proposed to identify the cause of the fault. The proposed method has been applied to the classic benchmark Tennessee Eastman process with and without per...

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call