Abstract

In this work, an innovative approach based on the estimation of the photovoltaic generator (GPV) parameters from the Bald Eagle Search (BES) optimization algorithm, associated with a support vector machine (SVM) classification algorithm, allowed to highlight a new tool for the classification of the signatures of shading and moisture PV defects. It recognizes signatures generated by the GPV in healthy and erroneous operation using the optimized parametric vector and classifies defects using the same optimized vector. The technique emphasizes the resilience of parameter estimate in terms of error on all parameters. The classification accuracy is 93%. The residuals between the estimated curve in healthy operation with a minimum error of the order of 10-4 and the one at fault are used as an indicator of faults.