The unexpected in-service failure of fluid pump end of fracturing pump motivated the present investigation. The model of three-cylinder single-action fluid pump end had been established by using the Pro/E software for improving the level of fracturing pump design. The combined use of fracture mechanics concepts as well as the finite element method demonstrated that local failure was due to the specific intersection region between plunger-chamber and cylinder-cavity. The predicted fatigue lives based on the FE stress analysis agree well with the application observations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.