Abstract

The behavior of double-angle stringer-to-floor-beam connections in riveted railway bridges is examined experimentally. A series of static and fatigue tests were performed on three full-scale bridge parts taken from an old riveted railway bridge. The results of the static tests reveal that the amount of end moment developed in these connections as a result of their rotational stiffness could be considerable. As a result of the cyclic variation in this moment, fatigue damage might develop in these connections. This damage was, however, observed to have a fairly low propagation rate and did not immediately reduce the load-carrying function of the connections.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.