Abstract

Objective Fatigue testing of adhesive bonds to tooth structures in conjunction with bond strength testing can provide more useful information for examining the effectiveness of dental adhesives. The purpose of this study was to determine the shear bond strength (SBS) and shear fatigue limit (SFL) of composite to enamel bonds using modern adhesive systems. Methods Twelve specimens each were used to determine 24-h resin composite (Z100-3M ESPE) to enamel shear bond strengths with an etch-and-rinse system (ERA), Adper Single Bond Plus (SB), and four self-etch adhesives (SEA)—Adper Prompt-L-Pop (PLP), Clearfil SE (CSE), Clearfil S 3 (CS3) and Xeno IV (X4). A staircase method of fatigue testing was used in a four-station fatigue cycler to determine the SFL of composite to enamel bonds with the adhesives (16–20 specimens for each adhesive) at 0.25 Hz for 40,000 cycles. ANOVA and Tukey's post hoc test were used for the SBS data and a modified t-test with Bonferroni correction was used for comparisons of the SFL. Results The SBS and SFL of the etch-and-rinse system were significantly greater ( p < 0.05) than those of the four self-etch adhesives. The SBS and SFL of CSE were also significantly greater than for the other three self-etch systems. The ratio of SFL to SBS was highest with the etch-and-rinse system and the ratio became increasing smaller in the same order that the values for SBS decreased with the self-etch systems. Significance The lower fatigue limits for composite to enamel bonds obtained with the self-etch adhesive systems may indicate that greater enamel margin breakdown will occur with restorations where these systems are used for bonding.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call