Abstract

The influence of factors such as ramp time, hold time, and temperature on isothermal fatigue of low-tin lead-based solder is investigated. Ways to extrapolate fatigue life are demonstrated. Decrease of frequency below 10/sup -2/ Hz is shown to lead to the reduction in the number of cycles to failure. The relation between N/sub f/ and frequency may be described by Eckel's relation. The effect of frequency is a function of strain range; therefore, the frequency-modified Coffin-Manson relation is not applicable to this solder at strains studied. Hold time dramatically reduces the number of cycles to failure and leads to the saturation in the N/sub f/. The method to calculate this limit is developed. The activation energy is a function of cycling conditions. High strain rates and high strain ranges lead to mixed transgranular-intergranular fracture. Activation energy, which is 24-26 kJ/mol. at low strain ranges and at all strain ranges with low strain rates (slow cycling or hold time in the cycle), can be used for isothermal fatigue data extrapolation of this solder. >

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.