Abstract

Using a commercial, electrodeposited copper film of 12 μm thickness, tensile tests, fatigue tests and static loading tests were performed. The elastic modulus, two types of yield strengths, tensile strength and strain-hardening exponent were obtained. Fatigue tests were performed at four levels of mean stresses and cyclic plastic strain and ratcheting strain (monotonic plastic strain) were measured continuously during the tests. Irrespective of mean stress, fatigue life can be well represented by the maximum stress. The monotonic plastic strain at fracture is nearly constant, irrespective of fatigue life or mean stress. Based on the results obtained, the reason why fatigue life can be well represented by the maximum stress is discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.