Abstract

In this study, the fatigue behavior of (±45°)3 filament-wound composite pipes with a surface crack under alternating internal pressure was investigated. Glass-reinforced plastic (GRP) pipes were made of E-glass/epoxy and tested in the open-ended condition. The pipes had a surface crack with a notch–aspect ratio of a/c = 0.2 and notch-to-thickness ratios of a/t = 0.25, 0.38, or 0.50 in the axial direction. Tests were carried out in accordance with ASTM D2992. This standard offers 25 cycles/min and a load ratio of R = 0.05. Tests were performed at three different load levels: 50%, 40%, and 30% of ultimate hoop stress. Whitening, leakage, and final failure of GRP pipes were observed, and fatigue test results were presented by means of S–N curves.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.