Abstract

The present work details a study performed for the determination of the causes of the premature rupture of a spring from an elevator door control mechanism. The study is based on the general methodology applicable to failure analysis. The results obtained in the experimental analysis and the analytical calculations lead to the conclusion that the fracture of the spring was caused by a mechanical fatigue mechanism whose origin is related to the presence in the periphery of the material of inclusions and superficial folds (stress concentrators), probably aggravated by the tensional state derived from the lack of alignment in the application of the load on the spring with respect to its axial axis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.