Abstract

Abstract The following paper is an engineering failure analysis of an adjustment pin used in a leg press exercise machine. The pin is used to allow adjustment of the machine for people of different heights. It was modeled as a cantilever beam subjected to varying forces depending on the weight stack setting. The fracture occurred at a point of localized stress concentration. The analysis shows an elastic stress concentration of 1.67 which would cause plastic deformation and a fatigue stress concentration of 1.38 that led to the eventual fatigue failure. Based on actual user data, a block loading analysis was used to calculate a pin lifetime of approximately one year. The pin actually failed after 1 1 2 years of use. Design changes are recommended to reduce the size of the stress concentration and subsequently increase the life of the adjustment pin. © 1998 Elsevier Science Ltd. All rights reserved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.