Abstract

Two separately failed electrical connector pieces during a vibration test were received for failure analysis. Chemical composition, hardness values and microstructures of the each of the connector material indicate that the material of construction is a die cast aluminium-silicon type of alloy, closely matching with the standard ANSI/AA B380 alloy. Intergranular and faceted fracture features are observed and failure mechanism is found to be fatigue dominated. The connectors failed by impact fatigue arising out of the loosening of the connector assembly. This has happened by cavity formation and/or growth related microstructural degradation processes. Initial casting pores as well as microstructural degradations such as interconnected pores have developed in service and their successive growth, decohesion and interconnection of each of primary Si particles and Al-Fe-Mn precipitates (along precipitate-matrix interface) have led the initiation of the crack under fatigue loading. Brittle as-cast microstructure (as typified by the precipitate-matrix interfacial cracking), existing vibratory loading and absence of any rise in temperature in the system have assisted the initial cavity (crack) formation and/or growth. Moreover, initial fitment related looseness is an additional factor in initiating and propagating this damaging mechanism.

Highlights

  • 1 INTRODUCTION Plated connectors meeting the quality assurance (QA) requirements for electrical performance and cleared by inspection agency are used for one system integration

  • Fibrous type of fracture appearance seems to prevail on failed surfaces of both the connector 1 (Figs. 3 and 4) and connector 2 (Fig. 5)

  • 6 CONCLUSIONS This research investigates the fatigue failure perspective of connectors used in cable harnessing

Read more

Summary

Introduction

Plated connectors meeting the quality assurance (QA) requirements for electrical performance and cleared by inspection agency are used for one system integration. The said connectors are employed for specific job of cable harnessing. The connectors are mated to each other and the whole system is subjected to vibration test. Two connector pieces have found to be damaged and/or broken after the completion of vibration test at room temperature. Present work describes the failure analysis of two such separately failed connectors

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.