Abstract
The safety of a nuclear power plant against earthquakes can be improved by installing seismic isolation devices. As such seismic isolation devices handle seismic loads, however, displacements larger than those generated before the application of such devices may occur. Therefore, the seismic risks are likely to increase for some facilities. In particular, pipes that connect structures with seismic isolation devices to ordinary structures are likely to have higher seismic risks. The piping is affected by the behavior of the two supports, and damage may occur due to the displacement-dominant repeated behavior. In addition, to assess the low-cycle fatigue behavior of the piping system under seismic loads, it is essential to identify the relationships among the number of cycles, moment, and deformation angle until leakage occurs, through an in-plane cyclic loading test. In this study, an in-plane cyclic loading test was conducted to assess the fatigue behavior of a steel pipe tee against seismic loads from the correlation between the moment and the deformation angle.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.