Abstract

AbstractWhile the LCF behavior of austenitic steels used in nuclear power plants is already well investigated, the VHCF regime has not been characterized in detail so far. For this, fatigue tests on the metastable austenitic steel AISI 347/1.4550 were performed with a servo‐hydraulic testing system at test frequencies up to 980 Hz and with an ultrasonic fatigue testing system at a test frequency of 20,000 Hz. To compare these test results to the ASME standard fatigue curve (total strain amplitude vs. load cycles to failure), a fictitious‐elastic and an elastically plastic assessment method was used. The elaborated elastic–plastic assessment method generates good results, while a purely elastic assessment in the VHCF regime, commonly used in literature, leads to significantly nonconservative results. Moreover, phase transformation from metastable austenite into stable α′‐martensite can take place, and no specimen failure occurs in the VHCF regime. Consequently, for this material, a real endurance limit exists.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.