Abstract
The ferritic/martensitic steel F82H-mod has been push–pull fatigue tested at 200°C before and after homogeneous implantation of 400 appm helium at about 0.5 dpa and 250°C to assess the growth characteristics of short fatigue cracks and their impact on lifetime. Crack initiation and propagation on carefully polished specimen surfaces were monitored by a high resolution optical microscope during fatigue testing. Subsequent metallographic and microstructural investigations revealed crack initiation mainly along martensitic laths and transgranular crack propagation, partly affected by the orientation of martensitic bands in adjacent grains. A statistical analysis of the crack formation and propagation processes was performed. Irradiation has led to pronounced fatigue life reduction by a factor of ∼5 at higher strain ranges and to a moderate fatigue life enhancement at low strain ranges. This behavior can be understood by different types of microstructural barriers and their effect on crack formation and growth.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.