Abstract

The fate and removal of permethrin during conventional wastewater treatment were evaluated at pilot‐plant scale at different concentrations of mixed liquor suspended solids (MLSS) and, hence, different solids retention times (SRT). At feed concentrations of 0.26–0.86 µg L−1, the permethrin was removed by primary treatment at an efficiency rate of 37%, similar to previously reported data, and from 40% to 83% for secondary treatment, decreasing with decreasing SRT. Comparable ranges, from 37% up to 98%, have been reported for micropollutants with similar physicochemical properties to permethrin, such as galaxolide and tonalide. Little difference in removal was noted between the medium and low MLSS concentrations trials, the main difference in treated effluent permethrin concentration arising on changing from high to medium MLSS levels. This was attributed to the limited acclimatization period employed in these two trials, leading to higher levels of soluble organic matter in the treated water, with which the permethrin appeared to be associated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.