Abstract

The effect of lipid emulsions on prothrombin time in blood from anticoagulated patients was determined. Blood samples were obtained from 23 patients therapeutically anticoagulated with warfarin (prothrombin time 1.3-2.0 x control). Varying amounts of an intravenous lipid emulsion (Intra-lipid) were added to the blood to simulate concentrations seen in vivo with a constant lipid infusion. The prothrombin time was measured on the plasma from these samples and compared to the prothrombin time of the plasma samples without lipid. The mean decrease in prothrombin times were: 0.29 sec at 50 micrograms/ml, 0.23 sec at 100 micrograms/ml, and 0.29 sec at 200 micrograms/ml. All concentrations showed a statistically significant decrease (p less than 0.05) when compared to the control by the Scheffe test. Lipid emulsions appear to decrease the prothrombin times in anti-coagulated patients. The differences however, were small and not of clinical significance at the concentrations tested.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.