Abstract

Lymph node metastasis (LNM) detection can be automated using artificial intelligence (AI)-based diagnostic tools. Only limited studies have addressed this task for colorectal cancer (CRC). This study aimed to develop of a clinical-grade digital pathology tool for LNM detection in CRC using the original fast-track framework.The training cohort included 432 slides from one department. A segmentation algorithm detecting 8 relevant tissue classes was trained. The test cohorts consisted of materials from 5 pathology departments digitized by 4 different scanning systems.A high-quality, large training data set was generated within 7 days and a minimal amount of annotation work using fast-track principles. The AI tool showed very high accuracy for LNM detection in all cohorts, with sensitivity, negative predictive value, and specificity ranges of 0.980 to 1.000, 0.997 to 1.000, and 0.913 to 0.990, correspondingly. Only 5 of 14,460 analyzed test slides with tumor cells over all cohorts were classified as false negative (3/5 representing clusters of tumor cells in lymphatic vessels).A clinical-grade tool was trained in a short time using fast-track development principles and validated using the largest international, multi-institutional, multiscanner cohort of cases to date, showing very high precision for LNM detection in CRC. We are releasing a part of the test data sets to facilitate academic research.