Abstract

The processing of pulses with very fast risetimes for timing purposes involves many problems because of the large equivalent bandwidths involved. For pulses with risetimes in the 150 ps range (and full widths at half maximum (FWHM) of 400 ps) bandwidths in excess of 1GHz are required. Furthermore, these very narrow pulses with current amplitudes as small as 1 mA carry very small charges (<10/sup -12/ coulomb), therefore, requiring very sensitive trigger circuits. The difficulty increases when timing characteristics in the picosecond range are sought especially when a wide input signal amplitude range causes a time-walk problem. The fast timing discriminator described has a time-walk of approximately +-75 ps over the input signal range from 80 mV to 3V. A schematic of the discriminator is included, and operation and performance are discussed.