Abstract

A two-dimensional perturbation method with regionwise flux expansion is developed and tested for the boiling water reactor fast shutdown margin calculation. The ways of generating the two-dimensional parameters for the unrodded bundles are tested to find the one that results in the most accurate eigenvalue of the single-rod-out condition. The use of the one-bundle-per-region flux expansion method gives more accurate results than the ring-regionwise flux expansion method. The first four strongest control rods chosen by this method using one-bundle-per-region flux expansion always contain the top four strongest rods predicted by SIMULATE-3 three-dimensional calculations. The strongest rod is always correctly predicted, and the differences in shutdown margin predictions are <1 mk for all the cases tested. The time saved by using the two-dimensional perturbation method rather than the direct three-dimensional full-core calculation is a factor of ∼10 and even more for larger core loadings. By using correct two-dimensional parameters, the accuracies of the perturbation method itself in the calculations of the eigenvalue and the neutron flux distribution are also tested. It is found that the errors are very small even for such a strong perturbation in the shutdown margin calculation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.