Surface-barrier structures based on high-purity epitaxial GaAs layers with an ultrahigh-molecular-weight polyethylene converter were tested as fast-neutron detectors. The α-particle spectra and the response to fast neutrons were measured under exposure to a 241Am−Be source. The detectors demonstrated a high neutron-detection efficiency (1.22 × 10−3 counts/neutron) and an acceptable ratio of the signal to γ‑ray background (approximately 40). The possibility of using such detectors at temperatures as high as 120°C was shown.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.