Abstract

In this study, we aimed to report the feasibility and quality of fast (unenhanced < 10-min duration) magnetic resonance imaging (MRI) for the detection of lymphadenopathy in non-sedated children with suspected tuberculosis (TB). This was a prospective study that involved children (< 13years of age) hospitalised at Red Cross Children's Hospital with suspected pulmonary TB who were referred for a fast MRI of the chest. The limited short-duration MRI protocol included coronal short tau inversion recovery (STIR) and axial diffusion-weighted imaging (DWI) sequences with additional axial STIR and axial and coronal T2 sequences if the patient was compliant. The scan time was capped at 10min and a study was considered successfully completed when DWI and STIR images were obtained in axial planes. MRI quality was recorded as 'acceptable quality'; 'poor quality, but readable'; and 'non-diagnostic'. Of the 192 fast MRI protocol scans, 166 (86%) were successfully completed within the 10-min allotted scan period. There was no age or sex difference between successful and unsuccessful studies. The mean duration of successful scans was 6.5min (standard deviation = 1.5min, range = 4-10min). Fast (sub-10-min scan) MRI is feasible for diagnosis of lymphadenopathy in non-sedated children in the setting of suspected TB, including those below 6years of age.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call