Abstract

PurposeTo validate a novel deformable image registration (DIR) method for online adaptation of planning organ-at-risk (OAR) delineations to match daily anatomy during hypo-fractionated RT of abdominal tumors. Materials and methodsFor 20 liver cancer patients, planning OAR delineations were adapted to daily anatomy using the DIR on corresponding repeat CTs. The DIR’s accuracy was evaluated for the entire cohort by comparing adapted and expert-drawn OAR delineations using geometric (Dice Similarity Coefficient (DSC), Modified Hausdorff Distance (MHD) and Mean Surface Error (MSE)) and dosimetric (Dmax and Dmean) measures. ResultsFor all OARs, DIR achieved average DSC, MHD and MSE of 86%, 2.1 mm, and 1.7 mm, respectively, within 20 s for each repeat CT. Compared to the baseline (translations), the average improvements ranged from 2% (in heart) to 24% (in spinal cord) in DSC, and 25% (in heart) to 44% (in right kidney) in MHD and MSE. Furthermore, differences in dose statistics (Dmax, Dmean and D2%) using delineations from an expert and the proposed DIR were found to be statistically insignificant (p > 0.01). ConclusionThe validated DIR showed potential for online-adaptive radiotherapy of abdominal tumors as it achieved considerably high geometric and dosimetric correspondences with the expert-drawn OAR delineations, albeit in a fraction of time required by experts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.