Abstract

The detection of amplitude and phase information in a single phase AC system is quite challenging due to the lack of quadrature component available in multi-phase AC systems. To produce the reliable quadrature component of the single phase AC system with harmonic noises, a derivative quadrature generator with appropriate filters is proposed. A low pass filter (LPF) optimizing the reductions of total harmonic distortion (THD) and response time of sensed signals was found, surveying generalized n-th order filters. To nullify phase shift of the LPF, an all pass filter was adopted. By simulations and experiments for the proposed phasor detector at 60 Hz, a fast time response of less than 8 ms was achieved under severe THD of 9.3 %.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.