Abstract
In this work, a new, non-intrusive, increased sensitivity technique based on air-coupled ultrasonics was developed to measure the falling liquid film thickness. Air-coupled transducer of frequency 1 MHz was used to make static and dynamic measurements of water level/film thickness. The air-coupled method were compared with a metal-side contact ultrasonic approach as well as calculating water levels in the collection tank. The falling film thickness measurement over inclined plate was used in this study. Measurement of film thickness was taken at flow rates in the range of 0.34–0.9 lpm. Relatively good agreement was found between the readings, which validates the dynamic measurement capability of the new technique. The technique was applied to measure the horizontal tube falling film thickness for falling film Reynolds number ranging from 130 to 350, at different circumferential angles ranging from 40° to 130° and at tube spacing of 5 mm and 15 mm. Measurements were compared with correlations available in the literature and found to be in good agreement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.