Abstract

Among the dietary strategies to overcome adiposity and obesity, the omission of carbohydrates in low-carbohydrate, high-fat diets (LC-HFDs) has been proposed as a tool for weight loss [1]. Popular weight loss guidebooks, including the Atkins diet books [2], claim that the lack of carbohydrates in LC-HFDs always triggers ketosis which would contribute to the weight-reducing effects of these diets. However, this theory was widely criticized in literature. Apart from attempts to reduce body weight with LC-HFDs, ketogenic LC-HFDs are also used to intentionally induce ketosis in patients with epilepsy and lately also as a potential beneficial treatment in other neurological diseases such as Alzheimer’s and Parkinson’s disease [3]. Both indications to use LC-HFDs are subject to intense research including rodent models. Quantification of ketosis in these models often is a crucial part of the investigation. The method of choice to analyze the level of ketosis is measurement of β-hydroxybutyrate (HBA), acetone and acetoacetate, collectively known as ketone bodies. The gold standard to quantify ketone bodies is analysis of HBA in circulation and acetone in urine or breath. However, urine ketone dipstick tests are often used as a quick and noninvasive alternative to assess ketone body status in clinical practice. In humans, a large study in 21,000 healthy subjects demonstrated that analysis of urine by the dipstick method is a practical and sensitive screening tool also for detection of ketosis [4]. In rats, analysis of HBA and even breath acetone has been shown to be an accurate measure of mild to moderate systemic ketosis [5, 6]. However, many rodent studies use the urine dipstick method to analyze ketone body concentrations although, to the best of our knowledge, a systematic validation of this method has never been conducted in rodents. Likhodii and colleagues [6] measured ketone body concentrations in rat plasma (by an enzymatic assay) and rat urine (by the dipstick method). They state that the dipsticks failed to adequately predict the degree of systemic ketosis because they correlated only poorly with the levels of HBA in plasma. Employing a nutritional rat model, we have recently reported that induction of ketosis with LC-HFDs is not only dependent on the absence of carbohydrates but also on low dietary protein [7]. In this study, we had analyzed HBA in serum and acetone in urine by laboratory methods because the dipstick ketone body measurements yielded inconsistent results. We now decided to systematically investigate suitability of the dipstick method to analyze ketone bodies in rat urine. 12-week old male Wistar rats (n = 15; Harlan, Germany) were fed a ketogenic LC-HFD (Kliba Nafag; Provimi Kliba SA, Kaiseraugst, Switzerland). The composition of the diet was 92.8% fat, 5.5% protein and 1.7% carbohydrates (macronutrient specifications are given as a percentage of metabolizable energy). After 3 weeks on the diets, urine samples were collected by housing the rats individually without bedding on stable metal grids for 12 h. Samples for each rat were taken from spontaneous 12-hour cumulative urine in addition to serum samples. Presence of ketone bodies in urine was first measured with commercially available dipsticks (‘Ketostix’, (Bayer, Leverkusen, Germany) and ‘Ketodiabur Sticks’ (Roche, Basel, Switzerland)) as by manufactures instructions. The color intensity of the dipsticks was compared with a color chart and transferred to the indicated numerical value. Urine samples were then stored at –20 °C until quantification of acetone by headspace injection and subsequent GC/MS analysis (Laboratoriumsmedizin Dortmund, Dortmund, Germany). As a representative example, the figure shows the results of ketone body measurements in urine from 10 different rats. Laboratory measurement of acetone in urine and HBA in serum (data not shown) confirmed ketosis in all rats. Within the same samples, we found a large discrepancy between the results obtained from the dipsticks and the laboratory analysis. Interestingly, the dipstick method both underestimated and overestimated concentrations of ketone bodies in different rats. In some cases, the results from the dipsticks also varied considerably between the two manufacturers. Most strikingly, dipsticks from both companies did not reliably indicate presence of

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call