Abstract

Under in-plane loading conditions, two independent modes contribute to the failure of a spot weld: the in-plane shear mode and the in-plane rotational mode. In this work, the failures of both modes under large static load are examined individually. To study the combined failure of these two modes, two special test coupons are designed. The first coupon contains one spot weld. The second coupon contains five spot welds. Tests conducted in this work show that a very simple force-based failure criterion can be used to predict the failure of a spot weld under large in-plane combined static loads. Current multiaxial failure theory cannot explain this combined failure. This force-based spot weld failure criterion fits current automotive industry needs for body shell finite element application very well.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.