Abstract

To the Editor, The patient’s spouse gave informed consent for publication of this report. A 55-yr-old male sustained burns in a welding accident extending caudad from shoulder level over 65% of his body surface area. In the intervening two months, he required multiple surgeries, including debridement and skin grafting, a laparotomy for abdominal compartment syndrome, and a tracheostomy. Presenting on this occasion for further skin grafting, he was breathing easily and spontaneously through a size 8 fenestrated Shiley tracheostomy cannula (Covidien, Mansfield, MA, USA) capped with a decannulation plug. In the operating room, the fenestrated inner cannula was exchanged for a non-fenestrated tube. Shortly after this change, the patient indicated some dyspnea. A suction catheter was introduced and moderate amounts of sputum were obtained, after which the patient signalled at least partial relief. Following application of routine monitors, anesthesia was induced using sevoflurane in oxygen through a circle system connected to the tracheostomy tube, supplemented with midazolam 2 mg and propofol 30 mg iv. After induction, it was almost impossible to ventilate the patient’s lungs. We detected a markedly prolonged expiratory phase and made a working diagnosis of severe bronchospasm although minimal rhonchi were present. We administered rocuronium 50 mg iv, increased the inspired sevoflurane concentration to 4%, and administered salbutamol, magnesium sulphate, and small doses (50–100 lg) of intravenous epinephrine. Although the oxygen saturation remained [ 90%, little improvement was achieved in response to these measures. An 18-Fr suction catheter was introduced on at least three further occasions. Each time, a scant amount of sputum was obtained, but no improvement in ventilation resulted. We twice passed a fibreoptic bronchoscope, but saw no obvious impediment to ventilation, and the tracheobronchial tree looked normal. Interestingly, when the tracheostomy tube was disconnected from the circuit for suctioning or bronchoscopy, we observed the patient’s chest gradually fall with loud yet slow gas egress from the tracheostomy cannula, suggesting gas escaping under conditions of high intrathoracic pressure. Following each such thoracic decompression, ventilation was easier for the next two or three positive pressure inspirations. Eventually, an inspiratory:expiratory (i:e) ratio of about 1:10 was observed to allow sufficient time for expiration, such that ventilation was now possible, albeit with ongoing high airway pressures. To rule out a circuit or machine problem, ventilation was assessed with a manual resuscitator, which confirmed that the high airway pressures originated from either the tracheostomy cannula or the patient. A portable chest radiograph showed only bilateral lung hyperinflation. Although substantially hypercarbic (PetCO2 up to 93 mmHg), fortunately, the patient suffered no cardiovascular instability. Ultimately, a change of tracheostomy was planned given the poor response to treatment for bronchospasm, ongoing problems with positive pressure ventilation, evidence of air trapping, and the initial history of dyspnea with tracheostomy manipulation. Repeat bronchoscopy was performed by a different clinician using a videobronchoscope. The visual field was briefly obscured as the videobronchoscope was advanced beyond the distal end of the tracheostomy cannula, after which a clear view of the trachea was observed. At this point, the possibility of cuff herniation was considered. Direct laryngoscopy prior to tracheostomy J. A. Law, MD (&) C. Mariotti, MD T. Mullen, MD Dalhousie University/QEII Health Sciences Centre, Halifax, NS, Canada e-mail: jlaw@dal.ca

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call