Abstract

This work looks into the failure of a sliding metal gate and the current practice for installing such sliding gates. The root cause of the failure was fracture of an L-shaped stopper that is very commonly used in sliding metal gates. Although fatigue associated with repeated impacts due to gate opening and closing operations are often blamed for failure of L-shaped stoppers, single-impact bending fracture was implicated in the present case. Besides L-shaped stoppers, it is a common practice to install a small metal stopper in the floor track to prevent gate overrunning. The suitability of installing such stoppers in floor track is questioned in the present study.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.