Abstract

High strength steels used in prestressing concrete structures are not exempt from the effects induced by corrosion on the normal concrete reinforcement. Carbonation of surrounding concrete or mortar is not unlikely for prestressing tendons and strands. Moreover, these steels undergo to brittle fracture as a consequence of stress corrosion cracking phenomena. To evaluate if concrete carbonation can promote this kind of failure, constant load tests in bicarbonate aqueous solutions under anodic polarization were carried out on high strength steel wires. Microscopic examination pointed out that the wires exhibited a brittle fracture mode, while its natural feature is ductile, as indicated by air testing. Failure mechanism was evaluated by a fracture mechanic approach. Cracks initiation was attributed to an anodic dissolution mechanism, while its propagation, interpreted by means of the surface mobility theory, was related to interaction between hydrogen atoms and magnetite at a crack tip.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.