Abstract This is the second article in a two-part series on the causes of failure in electromechanical relays. Part I, in the February 2018 issue of EDFA, examines a variety of failures caused by the formation of oxide on contact surfaces. As the author explains, electric arcing in the presence of silicon oil or vapor creates SiO2 deposits in the contact region that build up over time. Here in Part II, the author presents examples of failures caused by nitrous gases, phosphoric acid crystals, and wax, which is often found on enameled copper wires.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.