Abstract
This paper presents failure investigation on reheater pendent SA213-T22 tubes through visual inspections, steam-side scale and tube wall thickness measurements, metallurgical examinations, and creep analysis. The investigations were carried out following subsequent tube failures of the reheater pendent region of a boiler unit. Interaction event of significant internal scale formation causing the higher metal temperature and external scale exfoliation as a result of high-temperature corrosion is identified to cause the failure of the reheater pendent tube. Prevention actions are recommended to avoid similar failures in the future.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.