Abstract

The current study assesses the root causes of hydrogen blisters on low strength carbon steel equipment. For this purpose, some experiments including hardness test, non-destructive test (NDT), metallography, and fractograpghy are conducted. The microstructure of two blisters is assessed by means of optical microscopy and scanning electron microscopy (SEM). The microstructural studies show that the steel plate has some inclusions and banded ferrite/pearlite structure. The energy dispersive x-ray spectroscopy (EDS) results indicate that these inclusions mainly contain Mn, S, Al, Ca, and Si. The results show that the inclusions and planar imperfections found in the NDT have been the nucleation locations for blisters in the plate. Remediation action plans are recommended to prevent further occurrence and growth of hydrogen blisters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.