Abstract

An austenitic stainless steel tank used for storing liquid nitrogen tetroxide (N 2 O 4 ) had shown leaks while in service. The repair welding of the tank could not extend the life of the tank much. The leaked portion was subject to detailed failure analysis using standard metallographic techniques. The results revealed that the failure was mainly due to stress corrosion cracking.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.