Abstract

The worm gear connecting bolts of refueling machines of a nuclear power plant, with implementing standard of ANSI/ASME B18.3 and ASTM A574-08 and strength grade of 10.9, fractured at the thread neck position after running for about 10 years, and means such as macro examination, chemical compositions analysis, hardness testing, metallographic examination and fracture analysis, were used to analyze the fracture property and reasons of the bolts. The results show that the fracture of the bolts is due to two-way bending fatigue fracture. Surface decarburization of the bolts and stress concentration at the bolt thread neck decreased the fatigue strength of this position and resulted in the initiation of fatigue cracks. By comprehensive analysis and stress estimating, it was concluded that the main reason for fracture of the bolts is that there was a biggap between the bolts and the bolt holes, which resulted in fatigue fracture of the worm gear connecting bolts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.