Abstract

Titanium tubes used in condensers in a nuclear power plant in China encountered abnormal wall thinning, and was thus forced to temporarily stop operation or it could bring about catastrophic safety problems. Most of the wall thinning happened at quite regular positions on the tubes and these failure tubes were located similarly in the condensers, indicating some common problems. To find out the root cause and mechanism of the thinning failure, we conducted surface deposit analysis, appearance inspection, microstructure analysis and composition analysis of the samples by means of X-ray diffraction (XRD), stereo microscope, scanning electron microscope (SEM) and Energy Dispersive Spectrometer (EDS). The results revealed that the wall thinning was primarily caused by eccentric contact wear and three-body contact wear rooted in processing defect of internal borings, corrosion products deposit and sagging, and foreign particles. Finally, countermeasures were proposed for repair and prevention.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.