Abstract

Failure analysis is carried out on a leaked Type 321 stainless steel pipe in the hydrogen-eliminated system of a nuclear power plant. Comprehensive characterizations are utilized to investigate the operation conditions, base materials and macro/micro-morphologies of the failed pipe. Two distinct areas of morphologies inside the pipe are observed and three types of inclusions of the base materials are identified. Analysis results revealed that root cause of the abnormal leakage of the stainless steel pipe was the pitting corrosion, which was induced by chlorides from coastal atmosphere. The relevant failure mechanisms of the leaked stainless steel are carefully discussed and effective countermeasures are put forward as well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.