Abstract
The cause of weld cracking in external cold water pipeline of condenser in a ±800kV converter station were analyzed by macro inspection, chemical composition analysis, hardness test, microstructure inspection, scanning electron microscopy and energy spectrum test methods.The results show that the main reason for the cracks is that the material and manufacturing process are not qualified, and the welding process is not good. Corresponding control measures are put forward to avoid similar failures from happening again.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: E3S Web of Conferences
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.