Abstract

Concentrating solar power (CSP) is a technology seen key to achieve the worldwide energy transition targets. Although it is a mature robust technology, different failures in CSP plant have been reported in the literature to visualize potential point of maintenance interest. Following the same philosophy, this paper reports a failure occurred at a CSP storage pilot plant, where leakage and ignition of different joint balls suddenly occurred after several hours of testing. The experimental assessment carried out confirmed spontaneous ignition of the heat transfer fluid-soaked insulation material of the piping after leakage. The results of this study emphasize the significance of proactive maintenance and daily inspections in solar fields.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.