Abstract

The mains reasons for internal corrosion failure and cracking of the tee in shale gas transportation platform have been proposed based on macroscopic analysis, physical and chemical property test, metallographic examination, Scanning Electron Microscope analysis, X-ray spectroscopy analysis and service condition analysis. The results show that corrosion occurring in the inner wall of tee was caused by the combined impacts of CO2 corrosion, sulfate-reducing bacteria (SRB) corrosion and erosion corrosion. The crack in the weld of the inner wall was mainly due to the Sulfate-reducing Bacteria Induced cracking.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.