Abstract
Failure analysis of SA-213TP347H steel tube for high-temperature reheater of 600MW supercritical boiler was studied by means of macroscopic analysis, chemical composition, mechanical properties, microstructure, scanning electron microscopy and energy spectrum analysis. The results show that the chemical composition, hardness and strength of the tube samples meet the limit of ASTM A213/A213M standard. The microstructure of tube-burst sample is austenite, there are some precipitates containing Cr and Nb element at the grain boundaries. The test results for the spare part sample near elbow show that the hardness exceeds the limit of SA-213TP347H steel, there are a lot of slip lines and some non-metallic inclusions containing S in the microstructure. It is concluded that solid solution treatment missing in its manufacturing is the main reasons for the fracture, which makes Cr precipitate on the grain boundary and form the Cr-depleted zone, which is easy to cause intergranular stress corrosion and lead to the tube burst.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.