Abstract

In order to analyse failures caused in multilevel metallized LSI devices. we developed the OBIC (optical beam induced current) observation technique using an infrared laser incident upon a backside of the chip which appears from a plastic package by being lapped and polished. We analysed the electrical rejects in the reliability stressing of surface mount plastic packages with this technique. The latch-up phenomenon in 4Mbit dynamic RAM with retrograded-well fabricated by a high energy (MeV) ion-implantation was also examined. The high latch-up immunity of the device with retrograded-well is confirmed by this analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.