Abstract

Failure of the duplex stainless steel piping system in oil and gas industry can have disastrous effects. In this study, a novel method of failure analysis of flow-induced vibration problem of in-serviced duplex stainless steel piping system is proposed. The proposed non-destructive technique is able to determine a suitable operating condition for continuous operation without failure. The technique relies on the combined operation of operational modal analysis, operating deflection shape analysis and linear elastic finite element analysis. The effect of different operating conditions for two distinct valve opening cases (i.e. fully opened and partially opened) on the dynamic stress is examined, and they are utilised for forecasting purpose in failure analysis. The result shows that maximum operating conditions are 360 and 400 mmscfd for fully opened and partially opened flow control valves, respectively. Beyond this limit, the piping system most likely will fail.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.