Abstract

Abstract The bi-cable reversible aerial ropeway had been built as a winch system exclusively for goods transport. During upwards transport the winch was brusquely stopped by the operator. This caused the winch rope to slack and eventually to fracture at the moment of the jerky stretching by the backward rolling carriage. The brakeless carriage sped downhill along the track rope and finally crashed into the lower station leading to the unfortunate death of the farmer sitting unlawfully in the carriage. The steel wire rope (∅ 6 mm, type 6 × 7-FC) showed no indication of the typical failure mechanism of moving ropes, i.e. fretting fatigue. The single wires were broken in almost the same cross section showing a mixture of conical and shear fractures. This unusual fracture pattern could have been either the consequence of a local pre-damage or of an excessive lateral pressure and bending at the cross point of two windings on the winch. The latter alternative was evaluated by a test setup, allowing continuous increase of the deflection angle β until fracture of the rope. As a rule of thumb for β The quantified susceptibility of the rope's ultimate load to lateral pressure at sharp bending can also support future investigations of similar failure cases and risk analyses.