Abstract

A description is given of a fail-safe ion chamber system designed to be part of the personnel safety system (PSS) for the Los Alamos Neutron Scattering Center (LANSCE) at the Los Alamos National Laboratory. It protects the occupants of experiment areas from large radiation doses caused by errant beam conditions during beam transport from the proton storage ring to the LANSCE neutron spallation target. The layered system consists of three types of highly reliable detector systems: a current limiter system located in the beam line, a neutron detector system located in experimental areas, and an ion chamber system located on the walls of the beam line tunnels. The ion chamber system is capable of shutting off the beam in less that 0.5 s, resulting in a worst-case personnel exposure of 0.005 Gys (0.5 rd). >

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.