Abstract

Experimental studies of the influencing factors on the lowest refrigerating temperature of a miniature co-axial pulse tube refrigerator have been carried out in this paper. The results show that with the decrease of the mole fraction of hydrogen in the hydrogen-helium mixture, the lowest refrigerating temperature decreases, and when the mole fraction of hydrogen is below 20%, the lowest refrigerating temperature is close to that obtained using pure helium. In addition, it is also found that the optimum frequency of the compressor is about 16.7 Hz for different hydrogen-helium mixtures. When the charge pressure of the compressor increases, the lowest refrigerating temperature decreases; however, the decreasing trend gradually slows down with the increase of the charge pressure. © 2005 Wiley Periodicals, Inc. Heat Trans Asian Res, 34(4): 219–225, 2005; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/htj.20065

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.